Thermal Camera Guide
Setting Up Your Surroundings
Create the Delta Before You Scan
A thermal camera does not detect water. It detects temperature differences.
Before you start searching for a leak, your first job is to create enough temperature difference between Object 1 — the water and Object 2 — the surrounding wall, floor or ceiling. We call that difference Delta.Simple field rule: aim for approximately 7°C or more difference where practical.
The exact temperatures are not important. What matters is creating enough separation for the water path to stand out from the surrounding surface.
Object 1Water
Heat or cold carried by the water path.
VS
= Delta
Object 2Surrounding Surface
Wall, floor or ceiling around the suspected leak.
Water
35°C
Wall
25°C
Delta
10°C
Don’t just point the camera and hope to find the leak. Create the conditions that make the leak visible.
Hot Water Leak — Make the Surroundings Colder
If the leaking water is hot, cool the surrounding wall, floor or ceiling so the temperature difference becomes stronger. EXAMPLE ONLY- Water: 35°C+
- Wall: cooled using air-conditioning
- Target: approximately 7°C+ difference
Method
- Run the air-conditioning as cold as practical.
- Allow the surrounding surfaces time to cool.
- Then scan for the hotter leaking water against the colder background.
Hot water + cold surface = strong thermal contrast.
Cold Water Leak — Make the Surroundings Warmer
If the leaking water is colder than the surrounding structure, warm the surrounding wall, floor or ceiling to increase the temperature difference. EXAMPLE ONLY- Water: around 20°C
- Wall: warmed above the water temperature
- Target: approximately 7°C+ difference
Possible methods
- Air-conditioning in heating mode.
- Controlled warm air from a hair dryer.
- Carefully controlled external heat where appropriate.
Important: Do not aggressively heat one small spot. This can create a misleading thermal pattern.
Cold water + warm surface = strong thermal contrast.
Leaking Shower Wet Seal — Create Contrast From Both Directions
- Turn the house air-conditioning as cold as practical.
- Allow approximately 15–30 minutes for the shower walls and surrounding surfaces to cool.
- Remove the shower grate.
- Inflate a party balloon slightly larger than the waste opening.
- Push the balloon into the waste to temporarily plug it.
- Run hot water into the shower tray.
- Allow the water level to rise and create head pressure against the wet-seal membrane.
- Scan the surrounding walls and floor with the Delta 7.
Hot water + cold surroundings = a strong, easy-to-read thermal pattern.
Final reminder