A thermal camera does not detect water. It detects temperature differences.

Before you start searching for a leak, your first job is to create enough temperature difference between Object 1 — the water and Object 2 — the surrounding wall, floor or ceiling. We call that difference Delta.
Simple field rule: aim for approximately 7°C or more difference where practical.
The exact temperatures are not important. What matters is creating enough separation for the water path to stand out from the surrounding surface.
Object 1Water Heat or cold carried by the water path.
VS = Delta
Object 2Surrounding Surface Wall, floor or ceiling around the suspected leak.
EXAMPLE ONLY — NOT TARGET TEMPERATURES
Water 35°C
Wall 25°C
Delta 10°C

Don’t just point the camera and hope to find the leak. Create the conditions that make the leak visible.

HOT WATER

Hot Water Leak — Make the Surroundings Colder

If the leaking water is hot, cool the surrounding wall, floor or ceiling so the temperature difference becomes stronger. EXAMPLE ONLY
  • Water: 35°C+
  • Wall: cooled using air-conditioning
  • Target: approximately 7°C+ difference

Method

  • Run the air-conditioning as cold as practical.
  • Allow the surrounding surfaces time to cool.
  • Then scan for the hotter leaking water against the colder background.
Hot water + cold surface = strong thermal contrast.
COLD WATER

Cold Water Leak — Make the Surroundings Warmer

If the leaking water is colder than the surrounding structure, warm the surrounding wall, floor or ceiling to increase the temperature difference. EXAMPLE ONLY
  • Water: around 20°C
  • Wall: warmed above the water temperature
  • Target: approximately 7°C+ difference

Possible methods

  • Air-conditioning in heating mode.
  • Controlled warm air from a hair dryer.
  • Carefully controlled external heat where appropriate.
Important: Do not aggressively heat one small spot. This can create a misleading thermal pattern.
Cold water + warm surface = strong thermal contrast.
HOT VS COLD

Leaking Shower Wet Seal — Create Contrast From Both Directions

  1. Turn the house air-conditioning as cold as practical.
  2. Allow approximately 15–30 minutes for the shower walls and surrounding surfaces to cool.
  3. Remove the shower grate.
  4. Inflate a party balloon slightly larger than the waste opening.
  5. Push the balloon into the waste to temporarily plug it.
  6. Run hot water into the shower tray.
  7. Allow the water level to rise and create head pressure against the wet-seal membrane.
  8. Scan the surrounding walls and floor with the Delta 7.
This creates hot water inside the shower against colder surrounding surfaces. If water escapes through the membrane, the heat moving with the water can become extremely obvious on the thermal camera, almost like lava moving through the structure.
Hot water + cold surroundings = a strong, easy-to-read thermal pattern.
Final reminder

Build contrast safely.

Hot water? Cool the background.Cold water? Warm the background. Need stronger contrast? Increase the temperature difference safely. The goal is not to reach one specific temperature. The goal is to create enough Delta for the leak pattern to stand out.
 